| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 1080 View | HydraBID (Standalone) | Create New Assembly | None | None | When trying to create a new assembly, this error shows...But I am already in the Assembly Sheet of the Complete Parts List
|
|
| Card 1079 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | None | Failure at Step 5a.3b |
|
| Card 1078 View | HydraCAD (Revit Based) | Add Device | Select | None | I updated my database and I still get the old valve |
|
| Card 1077 View | HydraCALC (Standalone) | Print Final | Results | Discrepancy | Reviewing the results you notice a discrepancy between the k-factor of an equivalent k versus a sprinkler head using that equivalent k-factor
In the example below, EQ02 has a k-factor of 5.37. Reference point 1 is supposed to use the k-factor of EQ02 (5.37) but in fact is using a different value (5.36).
|
|
| Card 1076 View | HydraCAD (Revit Based) | Couplings | Add Couplings | None | No error, but when trying to use Add Couplings, Revit stops responding and the couplings are never placed. |
|
| Card 1075 View | HydraLIST (Revit Based) | Tag Setup | Ok | None | ERROR: No fittings were found on the selected pipe
|
|
| Card 1074 View | HydraCAD (Revit Based) | Hangers | Ok | None | No error, but when trying to put a seismic brace on a vertical pipe, it won't place itself down. It keeps prompting to make a selection. |
|
| Card 1073 View | HydraLIST (Standalone) | Process | None | None | After finishing a process in HydraLIST, no report appears afterwards. (HydraVIEW does not open) |
|
| Card 1072 View | HydraCAD (Revit Based) | Hangers | None | Unhandled Exception | When selecting the Hangers button, this error displays.
|
|
| Card 1071 View | HydraCAD (Revit Based) | Sleeves | None | None | No error, but when selecting the Sleeves button, the loading circle / hourglass will appear then disappear. But nothing will happen, the sleeves dialog box never comes up. |
|
| Card 1070 View | Entitlement (Security and Licensing) | None | None | Fingerprint | When attempting to activate an Entitlement you get the error; System.Invalid.OperationException: Failed to generate Fingerprint at HCADLicense.Form1.activate(String product_key, String user_token)
|
|
| Card 1069 View | Build 3D Risers (AutoCAD Based) | Create Legend | None | Unhandled Exception | After creating a legend for your 3D riser, you use the ILT command to insert a legend tag. It inserts the tag, but you get the error. You have to click CONTINUE then repeat the command to place another one. Unhandled exception has occurred in a component in your application Arithmetic operation resulted in an overflow Application does not support just-in-time (JIT)
|
|
| Card 1068 View | HydraCAD (Revit Based) | Hangers | Dialog Box | None | Hanger Assembly dropdown list is incomplete.
|
|
| Card 1067 View | Launching HydraCAD (AutoCAD Based) | Opening | None | Unhandled Exception | When opening HydraCAD, you get this error
Unhandled Exception...DAO32Server...
|
|
| Card 1065 View | HydraCAD (Revit Based) | Couplings | Add Couplings | Command Failure For External Command | Command Failure for External Command... System.OutOfMemoryException
|
|
| Card 1064 View | HydraCAD (Revit Based) | Couplings | Add Couplings | Command Failure For External Command | Command Failure for External Command... System.NullReferenceException
|
|
| Card 1063 View | HydraCAD (Revit Based) | Add Device | None | Command Failure For External Command | Command failure for external command ... System.IO.FileNotFoundException ... File name 'AWSSDK'
|
|
| Card 1062 View | Display (AutoCAD Based) | Osnaps | None | Other | When drawing objects, you get these icons/images/boxes next to the drawn object. If you hover over it, it mentions an osnap option
|
|
| Card 1061 View | HydraCALC (Revit Based) | Hydraulic Calculations | Continue | Runtime Error |
Calculation stops at Step 1a.4 - calcing total lengths Can be accompanied with a "Runtime error 5 - invalid procedure call or argument" or "Runtime error 6 - overflow" |
|
| Card 1060 View | HydraKEY (Security and Licensing) | Installation | None | None | HydraKEY icon disappears from the desktop when trying to run the application after install.
|
|