All Cards
* On smaller devices swipe left to view hidden table data
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 800 View | All products (Security and Licensing) | None | None | Ff60 Or Ff3 Or Rh60 Or Rsn60 Or Rl60 | Hydratec Security Lock Error
For example:
|
|
| Card 798 View | HydraBID (Standalone) | Open | None | None | when picking New Take Off Sheet
|
|
| Card 797 View | HydraCALC (Revit Based) | Calculation Process | Continue | Unhandled Exception | When picking the continue button one gets an error message "Unhandled Exception... Item has already been added. Key in Dictionary. 'a number' Key being added: 'same number' |
|
| Card 796 View | HydraCALC (Revit Based) | None | None | Bad Location Of K-Factor | Bad location of K-Factor
|
|
| Card 795 View | HydraCAD (Revit Based) | Spacing and Layout | Select | 0 |
|
|
| Card 176 View | Listing (AutoCAD Based) | Start Autolist | None | Failed To Launch |
"AutoLIST Failed!... Please run Listing CheckUps"
This message is shown when running the AutoLIST process, but checkups didn't find any errors AutoLIST Failed |
|
| Card 74 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Step 2.3 - After one pass through calculations Miscfunc hangs.... Also possibly "Hydraulic Engine not responding" and a "Runtime Error 62 input past end of file" |
|
| Card 71 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | When starting AutoCALC, it stops in the v50 Fuel Gauge at step 1a.4 - Calculating Total Lengths. Working on the pipe from node #### to node #### with a fitting string of ...
May be followed by a Runtime Error 13 or Runtime Error 5 |
|
| Card 660 View | HydraCALC (Standalone) | Calculate | Calculating | Process Error | Primary calc results are shown, and when selecting OK to continue back to the calc input screen, the two messages below are displayed, twice;
"The designated source node was not found in the list of pipes" OK "Calculation failed for an unknown reason" OK Process Error Hydcalc |
|
| Card 545 View | Piping (AutoCAD Based) | Auto Line | None | No Connectable Heads | No connectable heads found within distance specified for the line illustrated, or heads were already connected ...
No connectable heads message comes up, even when there are obviously heads that can be connected. Can also be error stating Please re-select line away from other lines |
|
| Card 186 View | Listing (AutoCAD Based) | Start Autolist | None | Unhandled Exception | AutoCAD Error Aborting FATAL ERROR: Unhandled Access Violation Reading 0x00e0 Exception at [hex code here] Acad 2019 hex code; 2D92713Eh Fatal Error
Hex code a51b726eh Or no error at all. Autocad freezes then crashes without an error other than the AutoCAD Error Report
A software problem has caused AutoCAD to close unexpectedly |
|
| Card 284 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Copy and Paste takes forever, slow process |
|
| Card 472 View | Cleanup (AutoCAD Based) | Draw Pretty Pipes | None | None | Unhandled exception has occurred in a component ... eBadLineTypeName The Pretty Pipe setup window will not open up. |
|
| Card 351 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Unable to select ceiling grid intersections when using Align Crosshairs with Ceiling |
|
| Card 649 View | HydraCALC (Standalone) | None | None | Final printout pages in HydraVIEW have data which looks smushed or overlapping or compressed or garbled or jumbled
|
||
| Card 392 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | No error message but cutting in couplings breaks the pipe but does not insert the couplings block. |
|
| Card 276 View | 3D Modeling (AutoCAD Based) | Check Elevation | None | None | TOS block looks odd or has unusual insertion point or text is placed far away |
|
| Card 368 View | 3D Modeling (AutoCAD Based) | Check Elevation | None | None | Check Elevation Command > after picking a point Internal error !dbobji.cpp@6861:eNotOpenForWrite and Autocad closes |
|
| Card 389 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | Upon starting the Show 3D command (S3D) the drawing immediately switches to SE isometric, reports no errors but no 3D piping is visible. Even newly drawn pipe won't elevate.
Drawing successfully elevated to 3D. No errors were found |
|
| Card 550 View | Collaborate (AutoCAD Based) | Revit Toolkit | Retrieve Content | None | Retrieve HydratecRevitContent is missing from the Add-Ins - Hydratec pulldown menu in Revit
|
|
Page: