AutoCAD Based Listing (Ribbon/Toolbar/Location)

Button: Start Autolist Error Type: DAO Error

Description:

While running AutoLIST, the process hangs when cleaning up lines database



DAO Server - Error RSEdit

Call from 'AutoList :: CleanUpLinesDatabase (lineDB)'.

DAO Error:

No current record.


Then followed by the AutoLIST Failed!  Please run Listing Checkups





Solutions:


1.
Cause:

Unknown

Solution:

Trying to list the entire project created the error, however splitting it into 3 groups using system boundaries allowed the project to run through.

It is recommended to close AutoCAD and re-open to avoid an Acad crash the next time you run AutoLIST.




2.
Cause:

Not sure but a lot of welded lines tagged manually with "L" numbers. (probably caused a duplicate id)

Solution:

Start autolist change the default line number to something other than "L"