| Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
| Card 376 View | Listing (AutoCAD Based) | Listing Check Ups | None | None | Unknown Calculations toolb 51 |
|
| Card 450 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via HydraList | None | None | 1) 3D Details cannot handle a main with more than 9 sections. 2) May have a dot in ID name. (ex. SP.1) missing outlets Inserting Mains |
|
| Card 1276 View | Entitlement (Security and Licensing) | None | None | Fingerprint | When attempting to activate an Entitlement you get the error; System,Net.WebException: The remote server returned an error: (400)
|
|
| Card 1275 View | HydraKEY (Security and Licensing) | Log Out (Subscription) | None | None |
Unable to contact our servers to Log you out. Your subscriptions are still intact on this machine. It is neccessary to contact the server to release your subscriptions for use elsewhere. |
|
| Card 1123 View | Persistent Model (AutoCAD Based) | Export | None | Error Writing | Exporting a Persistent Model gives the following message. More than like the PM drawing gets saved anyway. Cannot Save! drawing path and filename might be OPEN. Pleace (sic) close amd (sic) try again. *Should be "Please close and try again"
|
|
| Card 1153 View | Persistent Model (AutoCAD Based) | Navis Model | None | None | When importing a Persistent Model into Revizto, none of the riser nipples are visible |
|
| Card 1152 View | Persistent Model (AutoCAD Based) | Navis Model | None | None | When reading a Persistent Model drawing in Revizto, the units are not correct |
|
| Card 462 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | When trying to size a pipe, you select the pipe and nothing happens or you get an 'Automation Error' message |
|
| Card 1274 View | Installation (AutoCAD Based) | Hydra_DAO_Install.EXE | None | Error 1935 | When trying to install the Hydra_DAO_Install.exe based on this HydraCARD; https://hydracards.hydratecinc.com/cards/card-864 You get this error;
Microsoft Visual C++ 2008 Redistributable Setup 0x80070005
Followed by this one;
An error occurred during setup Installation failed. |
|
| Card 1030 View | HydraCAD (Revit Based) | Add Device | Select | Revit Could Not Complete The External Command. | Command failure for External Command... Revit could not complete the external command
|
|