Ribbon/Toolbar (software) Button Function Error Type Description
Ribbon/Toolbar (software) Button Function Error Type Description
Card 80 View Calculations (AutoCAD Based) Start Autocalcs None Unhandled Exception

Unhandled Exception: eWasErased Finishing an Area after calculating. Hangs up in Size Pipe from Schedule

Card 1103 View Calculations (AutoCAD Based) Start Autocalcs None Unhandled Exception

When starting the AutoCALC process, you get the error; Unhandled exception has occurred in a componenet in your application

eOnLockedLayer

 

Card 1129 View Calculations (AutoCAD Based) Start Autocalcs None None

When starting the AutoCALC process, you get an error like this;

You are missing a --- refPoint to complete a JUMP. 

Clicking OK should allow the process to continue on

Card 126 View Calculations (AutoCAD Based) Start Autocalcs None None

When starting the AutoCALC process, you get the error Unhandled exception has occurred in a component of your application

Key cannot be null

Parameter name: key.

Expanding DETAILS shows this information;

Application does not support just-in-time (JIT)
debugging. See the end of this message for details.

************** Exception Text **************
System.ArgumentNullException: Key cannot be null.
Parameter name: key
   at System.Collections.Hashtable.Insert(Object key, Object nvalue, Boolean add)
   at HCAD_HUI_CALC.CalcClass_Utilities.GetNodesOfPipesThatAreVertical(String FitID, Calc_File myCalcFile)
   at CalcingNameSpace.AutoCalcForm.MakeCalcFiledataPart1(Database db, Calc_File& MyCalcFile)
   at CalcingNameSpace.AutoCalcForm.SetupCalcFile()

Card 1207 View HydraCAD (Revit Based) Tag Pipes None Command Failure For External Command

Command Failure for External Command... System.NullReferenceException

Card 103 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Step 9a.1 - Runtime Error 62 Input past end of file.

Card 110 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Step 9a.1 - Saving Raw Calc Data Auto- Program Load Error Could not initiate process called for by \Hes\HydraCalc\Ver50\Programs\Hyd_Prog.exe

Card 905 View 3D Modeling (AutoCAD Based) Show System Model None Fatal Error

 

Card 60 View Calculations (AutoCAD Based) Water Supply None Unhandled Exception

Unhandled exception: Length cannot be zero

Card 67 View Calculations (AutoCAD Based) Start Autocalcs None None

No message, but grid does not get set up with L and R markers, even though a grid. Pipe mislabled as to Input Type

Autopeak peaking hydracalc